N605

4 Channel 200 MHz Constant Fraction Discriminator

Datasheet

Home Modular Pulse Processing ElectronicsAnalogDiscriminators N605

Photo of N605
  • Four independent Constant Fraction Discriminators for fast detectors with sub-ns rise time

  • Independently adjustable discriminators parameters (T, W, Z)

  • Double pulse resolving time down to 4 ns

  • Fine threshold adjustment from -15 to -1000 mV

  • Fine walk correction with zero-crossing adjustment

  • Exceptional low walk jitter < 50 ps

  • Adjustable output signal width

  • CFD monitor output

  • Common veto input and individual gates for coincidence or anticoincidence options

The CAEN Mod. N605 houses four independent 20% Constant Fraction Discriminators (CFD) in 1-unit wide NIM. The module is intended for high resolution time measurements, where fast signals with rise time as low as 0.8 ns are involved. Those may involve the use of radiation detectors made of fast scintillators, PMT, microchannel plates and fast semiconductor detectors.

The module guarantees exceptional low walk jitter, lower than 50 ps, for signals spreading over a wide range of amplitude, from -5 V to -50 mV.

The unit is provided with independent threshold discriminators to reject signal baseline noise. Front panel test point and screwdriver permits the precise measurement of the threshold, in the range from -15 mV down to -1 V. Each channel can be adjusted for the zero crossing level of the discriminator to minimize the time walk. Moreover the N605 has a CFD signal monitor output connector on the front panel to facilitate the correct adjustment of the working parameters.

Each channel has a fan-out of three timing output signals provided with NIM standard. The outputs can be selected to operate both in blocking and updating mode: the first is intended to minimize multiple triggering when slow scintillators are used, while the second is intended to reduce dead time in event of high rate condition. The board is provided with fast VETO input and individual GATE inputs to operate coincidence or anticoincidence logic conditions with the timing signal.


Ordering Options

Code Description
WN605XAAAAAA

N605 – 4 Channel 200 MHz Constant Fraction Discriminator

RoHS

You also may be interested in…

NIM8301

NIM8301

7U 12 slot smart fan unit 300/600 W Crate
NIM8302

NIM8302

5U 10 slot 150 W Compact Crate
NIM8305

NIM8305

2 Slot Switching 450 W Mini Crate
NIM8302P

NIM8302P

5U 5 slot 150 W Portable Crate
NIM8303

NIM8303

5U 12 slot 300/600 W Crate
NIM8306

NIM8306

2 Slot Switching 750 W Mini Crate
NIM8304

NIM8304

7U 12 slot smart fan unit Switching 2000 W Crate
Download Compare Tech. Spec.

Add to Wishlist
This product is already in your Wishlist
Browse the Wishlist

Request a Quote

Request a Quote

    Submit I’ve read and accept the privacy policy *

    Compare

    Close
    Image
    Name
    Package
    No. of Channels
    Function
    Updating
    Min Input (mV)
    Output Width (ns)
    I/O Delay (ns)
    Outputs
    Input Bandwidth (MHz)
    In Conn.
    Out Conn.
    N840

    N840

    NIM

    null

    Leading Edge

    Selectable

    -5

    5 ÷ 40

    10

    2 + /1 NIM

    140

    LEMO

    LEMO

    N843

    N843

    NIM

    null

    Const. Fraction

    No

    -5

    15 ÷ 245

    n/a

    2 + /1 NIM

    n/a

    LEMO

    LEMO

    N842

    N842

    NIM

    null

    Const. Fraction

    No

    -5

    15 ÷ 245

    n/a

    2 + /1 NIM

    n/a

    LEMO

    LEMO

    N844

    N844

    NIM

    null

    Low Threshold

    No

    -3

    5 ÷ 90

    10

    2 + /1 NIM

    60

    LEMO

    LEMO

    V812

    V812

    VME

    null

    Const. Fraction

    No

    -5

    12 ÷ 206

    n/a

    2 ECL

    n/a

    LEMO

    Std. Flat

    N845

    N845

    NIM

    null

    Low Threshold

    No

    -3

    5 ÷ 90

    10

    2 + /1 NIM

    60

    LEMO

    LEMO

    V895

    V895

    VME

    null

    Leading Edge

    Selectable

    -5

    5 ÷ 40

    10

    2 ECL

    140

    LEMO

    Std. Flat

    N605

    N605

    NIM

    null

    Const. Fraction

    Selectable

    -20

    2 ÷ 500

    n/a

    3 NIM

    250

    LEMO

    LEMO

    N841

    N841

    NIM

    null

    Leading Edge

    Selectable

    -5

    5 ÷ 40

    10

    2 + /1 NIM

    140

    LEMO

    LEMO

    V814

    V814

    VME

    null

    Low Threshold

    No

    -1

    6 ÷ 95

    10

    2 ECL

    60

    LEMO

    Std. Flat

    Technical Specifications

    Close

    Packaging

    1U-wide NIM unit

    Input Channels

    4 inputs (negative polarity, 50 Ω impedance)

    Input linear range

    -20 mV ÷ -5 V

    Max input amplitude

    -10V

    Max input frequency

    250 MHz

    Threshold range

    -15 mV ÷-1 V

    Output width

    From 2 ns to 500 ns (jumper setting)

    Output rise time

    < 600 ps

    Output fall time

    < 950 ps

    Walk

    < ±30 ps on -50 mV ÷ -5 V input with 2.5 ns rise/fall time
    < ±25 ps on -50 mV ÷ -2 V input with 1.6 ns rise/fall time

    Constant Fraction

    0,2

    Double Pulse Resolution

    < 4 ns

    Transmission Delay

    Typically < 7 ns with 3 ns external delay

    Operating Temperature Range

    0 to 50°C.

    Transmission delay Temperature Sensitivity

    < ±10 ps/°C from 0 to 50°C.

    Footer

    CAEN S.p.A.

    PI 00864500467 | REA: LU 102690

    C.I.V.: 500.500€ | CDU A47Ø7H7

    IMQ Certification
    Cyber Essentials Plus

    About Us

    • Company Profile
    • Our policy
    • Sales network
    • Innovative Projects
    • Careers
    • How to reach us

    Resources

    • Documentation
    • Accessibility Statement

    Applications

    • High Energy Physics
    • Astrophysics
    • Neutrino Physics
    • Dark Matter Investigation
    • Nuclear Physics
    • Material Science
    • Medical Applications
    • Homeland Security

    Support

    • Getting Started with MyCAEN Portal
    • CAEN LHC Commitment

    News

    • News

    Contact Us

    • Contact

    Login

        
    • Privacy Policy
    • Cookie Policy

    Copyright © 2026 CAEN S.p.A. All rights reserved. Website by Addiction

    ✕