EASY Subsystem Power Supply Module
Magnetic field and radiation tolerant
32 3.2 kV / 0.5 mA channels
Common Floating Return
VMax and IMax set by trimmer
Channel protections: overvoltage, overcurrent, overtemperature
On/Off for each channel
Interlock capability
Local and remote 48V Service on/off
Please note: the A3535 has been superseded by the A5540A.
The CAEN Mod. A3535 is a 32 Channel 3.2 kV / 0.5 mA / 1.1 W Power Supply Board, developed for operation in magnetic field and radioactive environment. Each A3535 houses 32 channels, each rated 3.2 kV / 0.5 mA, with common floating return. The board is available in a negative (A3535N) and a positive (A3535P) version.
The output voltage can be set with 500 mV monitor resolution. For each channel, a voltage protection limit, SVMAX, can be fixed via software with 500 mV resolution, and the output voltage cannot be programmed beyond this value.
The outputs are available on an SHV connector, a 32-channel Radiall R317580 HV coaxial connector used on the Mod. A3535P/N. For further technical details, please refer to our connectors reference page.
Its safety features allow the module to perform as a current generator. All channels can be enabled or disabled through the Global Interlock logic. An Overvoltage or Undervoltage warning is issued when the output voltage differs from the programmed value by more than 3% of the voltage full scale range.
When a channel attempts to exceed the programmed current limit, Overcurrent detection signals it as being in “overcurrent” and puts it into TRIP status. The output voltage is then varied to keep the current below the programmed limit for a programmable TRIP time, after which the channel is switched off. If TRIP is set to “constant current mode”, the channel behaves like a current generator.
Finally, the Hardware VMAX value, which sets the maximum output voltage, can be fixed via a front panel potentiometer at the same common value for all the board channels, and can be read out via software.
|
Image
|
Name
|
No. of Channels
|
Connectors
|
No. max of boards per crate
|
Width (slots)
|
Max power per channel (W)
|
Iset/Imon resolution
|
Vset/Vmon resolution
|
Current Full Scale
|
Voltage Full Scale (V)
|
Max Ripple (mVpp)
|
|
|
A3501 |
12 |
SHV |
10 |
2 |
0.1 |
100 nA |
100mV |
1 mA |
100 |
30 |
|
|
A3535 |
32 |
SHV |
5 |
4 |
1.75 |
100 nA |
500 mV |
500 µA |
3200 |
30 |
|
|
A3512 |
6 |
CPE HV |
7 |
3 |
12 |
100 nA |
1 V |
1 mA |
12000 |
50 |
|
|
A3540 |
12 |
SHV |
10 |
2 |
4 |
100 nA |
500 mV |
1 mA |
4000 |
30 |
|
No. of Channels |
32 |
|
Polarity |
Positive / Negative depending on purchased version; common floating return |
|
Output Voltage |
0 ÷ 3.2 kV (connector output) |
|
Maximum Output Power |
1.1 W per channel |
|
Max. Output Current |
0.5 mA |
|
Voltage Set/Monitor Resolution |
500 mV |
|
Current Set/Monitor Resolution |
100 nA |
|
VMAX hardware |
0 ÷ 3.2 kV |
|
VMAX hardware accuracy |
± 2% of FSR |
|
VMAX software |
0 ÷ 3.5 kV |
|
VMAX software resolution |
500 mV |
|
Voltage Ripple |
< 50 mV pp From 10 Hz to 15 MHz at full load |
|
Voltage Monitor vs. Output Voltage Accuracy |
± 0.3% of reading ± 1 V |
|
Voltage Set vs. Output Voltage Accuracy |
± 0.3% of setting ± 1 V |
|
Current Monitor vs. Output Current Accuracy |
± 2% of reading ± 0.3 µA |
|
Current Set vs. Output Current Accuracy |
± 2% of setting ± 1 µA |
|
Weight |
3.2kg |