Background image

A3512

6 Channel 12 kV / 1 mA Power Supply Board

Request a Quote Add to WishlistView Wishlist

Home Power SupplyEASY (Embedded Assembly SYstem)EASY3000 HV BOARDS A3512

Photo of A3512
DatasheetDownloadCompareTech. Spec.

Highlights

  • EASY Subsystem Power Supply Module

  • Magnetic field and radiation tolerant

  • Six 12 kV / 1 mA channels

  • Channel floating up to 5 V between each other

  • VMax and IMax set by trimmer

  • Channel protections: overvoltage, overcurrent, overtemperature

  • On/Off for each channel

  • Interlock capability

  • Local and remote 48V Service on/off

Overview

The CAEN Mod.A3512 12 kV / 1 mA Power Supply Board is developed for operation in magnetic field and radioactive environment. One A3512 houses 6 individual floating (up to 5 V between each other) 12 kV / 1 mA channels. The output voltage can be set with 1 V monitor resolution.

If the output voltage differs from the programmed value by more than 3% of voltage full scale range, the channel is signalled to be either in Overvoltage and Undervoltage condition. Moreover, for each channel, a voltage protection limit SVMAX can be fixed via software with 1 V resolution and the output voltage can not be programmed beyond this value.

CPE HV connector

High Voltage Single Pin, 6 channels (Mod. A3512, A3512H)

Consult our connectors reference page for technical information.

The output current is monitored with 100 nA resolution; if a channel tries to draw a current larger than its programmed limit it is signalled to be in Overcurrent condition; the SY1527 system detects this state as a fault and reacts according to the setting of the TRIP parameter.

Safety features allows the module to perform as a current generator and includes:

Channels

can be enabled or disabled through the Global Interlock logic.

Overvoltage and Undervoltage warning

when the output voltage differs from the programmed value by more than 3% of voltage full scale range.

Overcurrent detection

When a channel attempts to exceed the programmed current limit, it signalled to be in “overcurrent” and enter in a TRIP status. The output voltage is varied to keep the current below the programmed limit for a programmable TRIP time, then the channel is switched off. If TRIP is set to “constant current mode”, the channel behaves like a current generator.

Overtemperature detection

It is possible to monitor board temperature and to check board status thought TEMPERR > 65°C. When the board status is TEMPERR all channels are switched off.

Hardware VMAX and IMAX

Maximum output voltage and maximum current value can be fixed, via front panel potentiometer, at the same common value for all the board channel. IMAX and VMAX values can be read out via software.


Ordering Options

Code Description
WE3512HXNAAA

A3512HN – EASY3000 H.V. channels -12 KV 1 mA (6ch) – low noise version

WE3512HXPAAA

A3512HP – EASY3000 H.V. channels +12 KV 1 mA (6ch) – low noise version

WE3512XAAAAA

A3512N – EASY3000 H.V. channels -12 KV 1 mA(6 ch)

WE3512XPAAAA

A3512P – EASY3000 H.V. channels +12 KV 1 mA(6 ch)

You also may be interested in…

A3802

A3802

128 Channel DAC Board
A3501

A3501

12 Channels 100 V / 1 mA Power Supply Board
A3535

A3535

32 Channel 3.2 kV / 0.5 mA / 1.1 W Board
A3540

A3540

12 Channel 4 kV / 1 mA Power Supply Board
Download Compare Tech. Spec.

Add to Wishlist
This product is already in your Wishlist
Browse the Wishlist
Request a Quote

Request a Quote

    Submit

    Compare

    Close
    Image
    Name
    No. of Channels
    Connectors
    No. max of boards per crate
    Width (slots)
    Max power per channel (W)
    Iset/Imon resolution
    Vset/Vmon resolution
    Current Full Scale
    Voltage Full Scale (V)
    Max Ripple (mVpp)
    A3501

    A3501

    12

    SHV

    10

    2

    0.1

    100 nA

    100mV

    1 mA

    100

    30

    A3535

    A3535

    32

    SHV

    5

    4

    1.75

    100 nA

    500 mV

    500 µA

    3200

    30

    A3512

    A3512

    6

    CPE HV

    7

    3

    12

    100 nA

    1 V

    1 mA

    12000

    50

    A3540

    A3540

    12

    SHV

    10

    2

    4

    100 nA

    500 mV

    1 mA

    4000

    30

    Technical Specifications

    Close

    No. of Channels

    6

    Polarity

    Positive (A3512P, A3512HP) or Negative (A3512N, A3512HN), with Floating return

    Output Voltage

    0 ÷ 12 kV (connector output)

    Max. Output Current

    1 mA

    Voltage Set/Monitor Resolution

    1 V

    Current Set/Monitor Resolution

    100 nA

    VMAX hardware

    0 ÷ 12 kV

    VMAX hardware accuracy

    ± 2% of FSR

    VMAX software

    0 ÷ 12 kV

    VMAX software resolution

    1 V

    Voltage Ripple

    • < 50 mVpp
    • < 20 mVpp (A3512H version)

    Voltage Monitor vs. Output Voltage Accuracy

    • Typical: ± 0.3% of reading ± 5 V
    • Maximum: ± 0.3% of reading ± 10 V

    Voltage Set vs. Output Voltage Accuracy

    • Typical: ± 0.3% of setting ± 5 V
    • Maximum: ± 0.3% of setting ± 10 V

    Current Monitor vs. Output Current Accuracy

    • Typical: ± 2% of reading ± 1 µA
    • Maximum: ± 2% of reading ± 2 µA

    Current Set vs. Output Current Accuracy

    • Typical: ± 2% of setting ± 1 µA
    • Maximum: ± 2% of setting ± 2 µA

    Weight

    3.5 kg

    Footer

    CAEN - Tools for Discovery Logo (RGB)

    CAEN S.p.A.

    PI 00864500467 | REA: LU 102690

    C.I.V.: 500.500€ | CDU A47Ø7H7

    CAEN Group logo (B&W)
    IMQ Certification
    Cyber Essentials Plus

    About Us

    • Company Profile
    • Our policy
    • Sales network
    • Innovative Projects
    • Careers
    • How to reach us

    Resources

    • Documentation
    • Accessibility Statement
    • Special Offers

    Applications

    • High Energy Physics
    • Astrophysics
    • Neutrino Physics
    • Dark Matter Investigation
    • Nuclear Physics
    • Material Science
    • Medical Applications
    • Homeland Security

    Support

    • Getting Started with MyCAEN Portal
    • Login / Register
    • Wishlist

    News

    • News

    Contact Us

    • Contact
    • Privacy Policy
    • Cookie Policy
    • Whistleblowing

    Copyright © 2026 CAEN S.p.A. All rights reserved. Website by Addiction

    ✕