A3050

2 Channel 8 V / 50 A / 300 W Power Supply Board

Request a Quote Add to WishlistView Wishlist

Home Power SupplyEASY - Radiation & Magnetic Field TolerantEASY3000/5000 LV Boards A3050

Photo of A3050
DatasheetDownloadCompareTech. Spec.

Highlights

  • EASY Subsystem Power Supply Module

  • Magnetic field and radiation tolerant

  • 2 floating 2 ÷ 8 V / 50 A channels

  • 300 W maximum output power per channel

  • VMax and IMax set by trimmer for each channel

  • On/Off for each channel

  • Channels individually controlled and protected

  • Line Drop Regulation on board panel

  • Interlock capability

  • 48 V Service local and remote on/off

Overview

The CAEN Mod. A3050 is a 2 Channel 8 V / 50 A / 300 W Power Supply Board, developed for operation in magnetic field and moderate radioactive environment. Each A3050 houses two floating channels with reversible polarity, each rated 8 V / 50 A with a maximum output power of 300 W per channel. The output voltage range at the connector is 2 ÷ 8 V, with 5 mV monitor resolution, and channel control includes various alarms and protections.

The board mounts vertical-contact MINI P/CLAW output connectors of the APP PC5933T type. For further technical details, please refer to our connectors reference page.

The board is provided with Remote Sensing Lines that compensate for the voltage drop over the connection cables.

Its safety features allow the module to perform as a current generator. All channels can be enabled or disabled through the Global Interlock logic. An Overvoltage or Undervoltage warning is issued when the output voltage differs from the programmed value by more than 3% of the voltage full scale range.

When a channel attempts to exceed the programmed current limit, Overcurrent detection signals it as being in “overcurrent” and puts it into TRIP status. The output voltage is then varied to keep the current below the programmed limit for a programmable TRIP time, after which the channel is switched off. If TRIP is set to “constant current mode”, the channel behaves like a current generator.

Finally, the Hardware VMAX and IMAX values, which set the maximum output voltage and the maximum current, can be fixed via software with 5 mV resolution, and the output voltage cannot be programmed beyond this value.


Ordering Options

Code Description
WE3050XAAAAA

A3050 – EASY3000 L.V. channels 8 V/50 A/300 W floating – APP Conn. (2 ch)

You also may be interested in…

A3016B

A3016B

6 Channel 8 V / 16 A / 90 W Power Supply Board
A3025

A3025

4 Channel 8 V / 25 A / 150 W Power Supply Board
A3100B

A3100B

1 Channel 8 V / 100 A / 600 W Power Supply Board
A3100HBP

A3100HBP

1 Channel 8-14 V / 50 A / 600 W Power Supply Board
A3602

A3602

3 Channel 7 V / 5 A / 35 W Power Supply Board
Download Compare Tech. Spec.

Add to Wishlist
This product is already in your Wishlist
Browse the Wishlist

Request a Quote

Request a Quote

    Submit

    Compare

    Close
    Image
    Name
    No. of Channels
    Connectors
    No. max of boards per crate
    Width (slots)
    Max power per channels
    Iset/Imon resolution
    Vset/Vmon resolution (mV)
    Current Full Scale (A)
    Voltage full Scale (V)
    Max Ripple (mVpp)
    A5001
    New

    A5001

    32

    RJ45

    10

    2

    1.3 W

    10 μA

    1

    0.260

    0 ÷ 5

    20

    A5009
    New

    A5009

    12

    APP30

    5

    4

    45 W

    10 mA

    5

    9.3

    1.5 ÷ 9.3

    20

    A3602

    A3602

    3

    DB37

    10

    2

    35 W

    10 mA

    5

    5

    2 ÷ 7

    5

    A3025B

    A3025B

    4

    Brass hexagon head bolt

    5

    4

    150 W

    100 mA

    5

    25

    2 ÷ 8

    10

    A3016

    A3016

    6

    APP 1317G4

    5

    4

    90 W

    10 mA

    5

    16

    2 ÷ 8

    20

    A3050B

    A3050B

    2

    Brass hexagon head bolt

    5

    4

    300 W

    100 mA

    5

    50

    2 ÷ 8

    10

    A3100

    A3100

    1

    APP PC5933T

    5

    4

    600 W

    100 mA

    5

    100

    2 ÷ 8

    10

    A3050

    A3050

    2

    APP PC5933T

    5

    4

    300 W

    100 mA

    5

    50

    2 ÷ 8

    10

    A3025

    A3025

    4

    APP PC5933T

    5

    4

    150 W

    100 mA

    5

    25

    2 ÷ 8

    10

    A3100HBP
    New

    A3100HBP

    1

    Brass hexagon head bolt

    5

    4

    600 W

    100 mA

    10

    50

    8 ÷ 14

    10

    A3006

    A3006

    6

    APP 1317G4

    5

    4

    90 W

    10 mA

    10

    6

    4 ÷ 16

    20

    A3016B

    A3016B

    6

    Brass hexagon head bolt

    5

    4

    90 W

    10 mA

    5

    16

    2 ÷ 8

    20

    A3100B

    A3100B

    1

    Brass hexagon head bolt

    5

    4

    600 W

    100 mA

    5

    100

    2 ÷ 8

    10

    Technical Specifications

    Close

    No. of Channels

    2

    Polarity

    Reversible

    Output Voltage

    2 ÷ 8 V (connector output)

    Max. Output Current

    50 A

    Voltage Set/Monitor Resolution

    10 mV

    Current Set/Monitor Resolution

    100 mA

    VMAX hardware

    2 ÷ 8 V

    VMAX software

    2 ÷ 8 V

    VMAX software resolution

    10 m V

    Voltage Ripple

    < 10 mV pp (@ full load)

    Voltage Monitor vs. Output Voltage Accuracy

    max. ±50 mV ±0.3% of reading

    Voltage Set vs. Output Voltage Accuracy

    max. ±50 mV ±0.3% of reading

    Current Monitor vs. Output Current Accuracy

    ± 1A ± 2% of reading

    Current Set vs. Output Current Accuracy

    ± 1A ± 2% of reading

    Load Regulation

    ± 0.3 % (with sense wires)
    ± 2 % (without sense wires)

    Output Power (per Channel)

    300 W

    Test Set Up

    • cable: length = 30m; diam.= 8mm (for both output and return) with sense wires connected
    • test load: >600W
    • load capacitance: 10µF electrolytic // 100nF ceramic (// to the load)

    Weight

    6.5 kg

    Footer

    CAEN - Tools for Discovery Logo (RGB)

    CAEN S.p.A.

    PI 00864500467 | REA: LU 102690

    C.I.V.: 500.500€ | CDU A47Ø7H7

    CAEN Group logo (B&W)
    IMQ Certification
    Cyber Essentials Plus

    About Us

    • Company Profile
    • Our policy
    • Sales network
    • Innovative Projects
    • Careers
    • How to reach us

    Resources

    • Documentation
    • Accessibility Statement
    • Legal and Compliance
    • Certifications

    Applications

    • High Energy Physics
    • Astrophysics
    • Neutrino Physics
    • Dark Matter Investigation
    • Nuclear Physics
    • Material Science
    • Medical Applications
    • Homeland Security

    Support

    • Getting Started with MyCAEN Portal
    • Login / Register
    • Wishlist

    News

    • News

    Contact Us

    • Contact
    • Privacy Policy
    • Cookie Policy
    • Whistleblowing

    Copyright © 2026 CAEN S.p.A. All rights reserved. Website by Addiction

    ✕