EASY Subsystem Power Supply Module
Magnetic field and radiation tolerant
One floating 2 ÷ 8 V /100 A channel
600 W maximum output power
VMax and IMax set by trimmer for each channel
On/Off for each channel
Channels individually controlled and protected
Line Drop Regulation on board panel
Interlock capability
48 V Service local and remote on/off
Screw Lock output connectors
The CAEN Mod. A3100B is a 8 V / 100 A Power Supply Board, developed for operation in magnetic field and moderate radioactive environment. One A3100B houses one floating (reversible polarity) 8 V / 100 A (600 W maximum output power) channel.
The connector output voltage range is 2 ÷ 8 V with 5 mV monitor resolution; channel control includes various alarms and protections.
The board is provided with Remote Sensing Lines to compensate for the voltage drop over the connection cables. If the output voltage differs from the programmed value by more than 3% of voltage full scale range, the channel is signalled to be either in Overvoltage and Undervoltage condition.
Moreover, for each channel, a voltage protection limit SVMAX can be fixed via software with 5 mV resolution and the output voltage can not be programmed beyond this value.
![]() |
Brass Hexagon head bold connector
Brass hexagon head set screw, M6x30mm connector for A3100B |
Consult our connectors reference page for technical information.
Safety features allows the module to perform as a current generator and includes:
| Channels |
can be enabled or disabled through the Global Interlock logic. |
| Overvoltage and Undervoltage warning | when the output voltage differs from the programmed value by more than 3% of voltage full scale range. |
| Overcurrent detection | When a channel attempts to exceed the programmed current limit, it signalled to be in “overcurrent” and enter in a TRIP status. The output voltage is varied to keep the current below the programmed limit for a programmable TRIP time, then the channel is switched off. If TRIP is set to “constant current mode”, the channel behaves like a current generator. |
| Hardware VMAX and IMAX |
Maximum output voltage and maximum current value can be fixed via software with 5 mV resolution and the output voltage can not be programmed beyond this value. |
|
Image
|
Name
|
No. of Channels
|
Connectors
|
No. max of boards per crate
|
Width (slots)
|
Max power per channels
|
Iset/Imon resolution
|
Vset/Vmon resolution (mV)
|
Current Full Scale (A)
|
Voltage full Scale (V)
|
Max Ripple (mVpp)
|
|
|
A3009B |
12 |
Screw lock connectors |
5 |
4 |
45 W |
10 mA |
5 |
9 |
2 ÷ 8 |
20 |
|
|
A3602 |
3 |
DB37 |
10 |
2 |
35 W |
10 mA |
5 |
5 |
2 ÷ 7 |
5 |
|
|
A3025B |
4 |
Brass hexagon head bolt |
5 |
4 |
150 W |
100 mA |
5 |
25 |
2 ÷ 8 |
10 |
|
|
A3009 |
12 |
APP 1317G4 |
5 |
4 |
45 W |
10 mA |
5 |
9 |
2 ÷ 8 |
20 |
|
|
A3009H |
12 |
APP 1317G4 |
5 |
4 |
45 W |
10 mA |
5 |
9 |
6 ÷ 14 |
20 |
|
|
A3016 |
6 |
APP 1317G4 |
5 |
4 |
90 W |
10 mA |
5 |
16 |
2 ÷ 8 |
20 |
|
|
A3050B |
2 |
Brass hexagon head bolt |
5 |
4 |
300 W |
100 mA |
5 |
50 |
2 ÷ 8 |
10 |
|
|
A3100 |
1 |
APP PC5933T |
5 |
4 |
600 W |
100 mA |
5 |
100 |
2 ÷ 8 |
10 |
|
|
A3009HB |
12 |
Screw lock connectors |
5 |
4 |
45 W |
10 mA |
5 |
9 |
6 ÷ 14 |
20 |
|
|
A3050 |
2 |
APP PC5933T |
5 |
4 |
300 W |
100 mA |
5 |
50 |
2 ÷ 8 |
10 |
|
|
A3025 |
4 |
APP PC5933T |
5 |
4 |
150 W |
100 mA |
5 |
25 |
2 ÷ 8 |
10 |
|
|
New A3100HBP |
1 |
Brass hexagon head bolt |
5 |
4 |
600 W |
100 mA |
10 |
50 |
8 ÷ 14 |
10 |
|
|
A3006 |
6 |
APP 1317G4 |
5 |
4 |
90 W |
10 mA |
10 |
6 |
4 ÷ 16 |
20 |
|
|
A3016B |
6 |
Brass hexagon head bolt |
5 |
4 |
90 W |
10 mA |
5 |
16 |
2 ÷ 8 |
20 |
|
|
A3100B |
1 |
Brass hexagon head bolt |
5 |
4 |
600 W |
100 mA |
5 |
100 |
2 ÷ 8 |
10 |
|
No. of Channels |
1 |
|
Polarity |
Reversible |
|
Output Voltage |
2 ÷ 8 V (connector output) |
|
Max. Output Current |
100 A |
|
Voltage Set/Monitor Resolution |
10 mV |
|
Current Set/Monitor Resolution |
100 mA |
|
VMAX hardware |
2 ÷ 8 V |
|
VMAX software |
2 ÷ 8 V |
|
VMAX software resolution |
5 m V |
|
Voltage Ripple |
< 10 mV pp (@ full load) |
|
Voltage Monitor vs. Output Voltage Accuracy |
max. ±50 mV ±0.3% of reading |
|
Voltage Set vs. Output Voltage Accuracy |
max. ±50 mV ±0.3% of reading |
|
Current Monitor vs. Output Current Accuracy |
± 1A ± 2% of reading |
|
Current Set vs. Output Current Accuracy |
± 1A ± 2% of reading |
|
Load Regulation |
± 0.3 % (with sense wires)± 2 % (without sense wires/LDR ON/SENSE OFF) |
|
Test set up |
cable: length = 30m; diam.= 8mm (for both output and return) with sense wires connected |
|
Output Power |
600 W |
|
Weight |