• Skip to main content
  • Skip to footer
CAEN logo light
  • About
    • Company Profile
    • Our policy
    • Sales network
    • Innovative Projects
    • Careers
    • How to reach us
  • Products
  • Resources
    • Documentation
    • Download
    • FAQ
    • Glossary
    • Certifications
    • Legal and Compliance
  • Support
  • Contact
All productsSpecial OffersForm FactorEducationalPower SupplyModular Pulse ProcessingDigitizer FamiliesFERS FamiliesDigital SpectroscopyCAEN SyS productsFirmware & SoftwarePowered CratesAccessoriesBrands
Background image

A5009

12 Channel 14 V / 5 A / 45 W Power Supply Board

Request a Quote Add to WishlistView Wishlist

Home A5009

Photo of A5009
DatasheetDownloadTech. Spec.

Highlights

  • EASY Subsystem Power Supply Module

  • Magnetic field and radiation tolerant

  • 12 floating 4 ÷ 14 V / 5 A channels (positive polarity)

  • APP30 connectors

  • 45 W maximum output power per channel

  • VMax and IMax set by trimmer for each channel

  • On/Off for each channel

  • Channels individually controlled and protected

  • Voltage Drop compensation via sense wires

  • Interlock capability

  • 48 V Service local and remote on/off

Overview

The CAEN Mod.A5009 12 Channel 14 V / 5 A Power Supply Board is developed for operation in magnetic field and moderate radioactive environment. One A5009 houses 12 positive 14 V / 5 A / 45 W maximum output power, channels. The connector output voltage range is 6 ÷ 14 V with 5 mV monitor resolution; channel control includes various alarms and protections. A 11.8V ± 0.1V hardware limit is available on request. The board is provided with Remote Sensing Lines to compensate for the voltage drop over the connection cables.

APP30 connector

APP30 1317G4 type connector for Mod.A3009HP

Consult our connectors reference page for technical information.

Safety features allows the module to perform as a current generator and includes:

Channels

can be enabled or disabled through the Global Interlock logic.

Overvoltage and Undervoltage warning

when the output voltage differs from the programmed value by more than 3% of voltage full scale range.

Overcurrent detection

When a channel attempts to exceed the programmed current limit, it signalled to be in “overcurrent” and enter in a TRIP status. The output voltage is varied to keep the current below the programmed limit for a programmable TRIP time, then the channel is switched off. If TRIP is set to “constant current mode”, the channel behaves like a current generator.

Hardware VMAX and IMAX

Maximum output voltage and maximum current value can be fixed via software with 5 mV resolution and the output voltage can not be programmed beyond this value.


Ordering Options

Code Description
WE5009XAAAAA

A5009 – EASY5000 L.V. channels 8V / 9A / 45W floating – APP Conn. (12 ch)

RoHS
Download Tech. Spec.

Add to Wishlist
This product is already in your Wishlist
Browse the Wishlist

Request a Quote

Request a Quote

    Submit

    Technical Specifications

    Close

    No. of Channels

    12, APP30 connectors

    Polarity

    Positive; full floating (return individually insulated with respect to earth)

    Output Voltage

    6 ÷ 14 V (connector output) 11.8V ± 0.1V hardware limit available on request; a label on the front panel indicates the hardware voltage limit installation

    Max. Output Current

    5 A

    Voltage Set/Monitor Resolution

    5 mV

    Current Set/Monitor Resolution

    10 mA

    VMAX hardware

    6 ÷ 14 V

    VMAX software

    6 ÷ 14 V

    VMAX software resolution

    5 mV

    Ramp Up

    from 0.1 V/s to 400 V/s with 0.1 V/s steps

    Voltage Ripple

    <20 mV pp on 10 µF // 0.1 µF 10 Hz-15 MHz

    Voltage Monitor vs. Output Voltage Accuracy

    max. ±30 mV ±0.3% of reading

    Voltage Set vs. Output Voltage Accuracy

    max. ±30 mV ±0.3% of reading

    Current Monitor vs. Output Current Accuracy

    ± 0.05A ± 2% of reading

    Current Set vs. Output Current Accuracy

    ± 0.05A ± 2% of reading

    Load Regulation

    ± 0.3 % (with sense wires) ± 2 % (without sense wires)

    Output Power (per Channel)

    45 W

    Footer

    CAEN - Tools for Discovery Logo (RGB)

    CAEN S.p.A.

    PI 00864500467 | REA: LU 102690

    C.I.V.: 500.500€ | CDU A47Ø7H7

    CAEN Group logo (B&W)
    IMQ Certification
    Cyber Essentials Plus

    About Us

    • Company Profile
    • Our policy
    • Sales network
    • Innovative Projects
    • Careers
    • How to reach us

    Resources

    • Documentation
    • Accessibility Statement
    • Legal and Compliance
    • Certifications

    Applications

    • High Energy Physics
    • Astrophysics
    • Neutrino Physics
    • Dark Matter Investigation
    • Nuclear Physics
    • Material Science
    • Medical Applications
    • Homeland Security

    Support

    • Getting Started with MyCAEN Portal
    • Login / Register
    • Wishlist

    News

    • News

    Contact Us

    • Contact
    • Privacy Policy
    • Cookie Policy
    • Whistleblowing

    Copyright © 2026 CAEN S.p.A. All rights reserved. Website by Addiction

    ✕