Specifically designed for neutron detectors as He3 in position sensitive application
19” rack unit (height = 2U)
External HV input on SHV connector (feeding the internal decoupling circuits)
Detector inputs on SHV connectors
Test input on BNC (1 pF charge injection capacitors)
Total gain 2.25 V/pc
Rate capability: >100 kHz per tube
Differential outputs on RJ45 connectors
Three available versions:
32 channels – R1443A
64 channels – R1443B
32 channels with 16 independent HV inputs (1 per tube) – R1443C
Complete position-sensitive 3He acquisition system in combination with R5560 digitizer
240 or 100 Vac, 50-60 Hz input available
The CAEN Mod.R1443 is a 32/64 channels Charge Sensitive Preamplifier in a 19ʺ rack unit. It has been developed in collaboration with Institut Laue-Langevin in Grenoble, France, and it is specifically designed for operating with neutron detectors as 3He or BF3 tubes. Given the number of input channels, it can handle up to 16/32 position-sensitive tubes, each tube having two outputs, one for each end. The pre-amplifier has an exponential time constant of 1 µs. This guarantees excellent performances even at high rates exceeding 100 kcps. The output of this preamplifier is typically readout by ADC and Digital Pulse Processing electronics in order to perform specific filtering to achieve the best charge, timing and axial position measurements. The R1443 is 120/230 V 50/60 Hz AC Powered.
Here you can find the link at the “MIRACLES detector prototypes and front-end electronics: integration, tests and some lessons learned” presented in DENIM (Design and Engineering of Neutron Instruments Meeting) on September 2023 at Forschungszentrum Jülich in Germany.
|
Image
|
Name
|
FORM FACTOR
|
NO. OF CHANNELS
|
DESCRIPTION
|
SENSITIVITY
|
COMPATIBLE DETECTORS
|
|
|
A1422H |
Single in-line package |
1 |
Low Noise Fast Rise Time Charge Sensitive Preamplifiers (SIP) |
1/5/45/90/400/450<br>mV/MeV (Si) |
Silicon (Si) |
|
|
A1424 |
Desktop |
1 |
Fast Charge Sensitive Preamplifier |
3.6 mV/fC |
Diamond |
|
|
A1422C/D |
Desktop |
8 |
Low Noise Fast Rise Time Charge Sensitive Preamplifier |
5 (mV/MeV) (Si) |
He3 / BF3 Tubes |
|
|
A1422 |
Desktop |
1 / 4 / 8 |
Low Noise Fast Rise Time Charge Sensitive Preamplifiers |
1/5/45/90/400/450<br>mV/MeV (Si) |
He3 / BF3 Tubes<br>Proportional Counters<br>Ionization Chambers<br>Segmented Silicon <br>Silicon (Si) |
|
|
A1429 |
Desktop |
64 |
Charge Sensitive Preamplifier |
20/45/90/200/400<br>mV/MeV (Si) |
GEM Segmented Silicon |
|
|
A1427 |
Desktop |
1 |
Low Noise Fast Current Neutron Flux Preamplifier |
FC: 700÷2500<br>(Trimmer adjustable)<br>PR: 500÷1500<br>(Trimmer adjustable) |
Fission Chambers<br>Proton Recoil |
|
|
A1422E/F |
Desktop |
2 / 4 |
Low Noise Fast Rise Time Charge Sensitive Preamplifiers |
200 mV/MeV (Si) |
Silicon (Si) |
|
|
A1442 |
Desktop |
16 / 32 |
Charge Sensitive Preamplifier |
Selectable 20/100<br>mV/MeV (Si) |
GEM Segmented Silicon |
|
|
New A1421 |
Desktop |
1 |
Preamplifier and Discriminator for 3He tubes |
30 mV/fC on HiZ<br>(15 mV/fC on 50 Ω) |
He3 / BF3 Tubes |
|
|
R1443 |
19” rack unit |
32 / 64 |
Preamplifier Unit for 3He tubes |
2.25 V/pC |
He3 / BF3 Tubes |
|
|
A1423B |
Desktop |
1 |
Wideband Preamplifier |
Selectable From<br>+18 dB to +54 dB |
Diamond PMT<br>Scintillators<br>SiPM / MPPC |
|
|
A1426 CARDARELLI |
Desktop |
1 |
Matched Charge Preamplifier |
Up to 5 mV/fC |
Diamond |
|
|
A1436 / A1436A |
Desktop |
1 / 8 |
Differential Input Low Noise Transimpedance Amplifiers |
Programmable<br>10<sup>9</sup>/10<sup>8</sup>/10<sup>7</sup>/10<sup>6</sup>/10<sup>5</sup>/10<sup>4</sup>/10<sup>3</sup><br>(V/A), 10<sup>9</sup> V/A (A1436 only) |
Diamond PMT / Scintillators<br>Silicon (Si) |
|
|
A1425 |
Desktop |
1 |
Fast Charge Sensitive Preamplifier |
3.6 mV/fC |
Diamond |
|
|
A422A |
Desktop |
1 |
Charge Sensitive Preamplifier with Timing |
5/30/60 mV/MeV (Si) |
Proportional Counters<br>Ionization Chambers<br>Silicon (Si) |
|
Mechanical |
|
|
Power consumption |
|
|
Detector input |
Accepts positive and negative input charge pulses from detectors and supplies the HV bias to the detector itself
|
|
HV In (Detector Bias) |
|
|
Test-In |
|
|
Preamplifier (Analog Out) |
|
|
Environmental |
Indoor use:
|