Optimized for SiPM
Number of channels: 64
Outputs: Digital output (dual ADC and dual TDC per channel) – selectable transmission mode. 1 multiplexed time trigger output, 2 ASIC trigger 0R outputs (64 channels, 2 levels)
Input Polarity: Positive
Temporoc is a 64-channel front-end ASIC designed to readout silicon photomultipliers (SiPMs) for particle time-of-flight measurement applications. Temporoc combines a very fast and low-jitter trigger with accurate charge and time measurements. Energy and time are digitized internally with a 10-bit ADC and 50ps-bin TDC. In total, Temporoc is capable of providing two distinct time tagging and two energy measurement of each event.
The concept of this ASIC is combining two measurement lines that won’t interfere one with each other to measure both first incident photon timing measurement and whole crystal light charge integration. Additionally, Temporoc features clustering triggers readout which could be useful for particle detection with monolithic scintillator.
An adjustment of the SiPM high voltage is possible using a channel-by-channel input DAC. It allows a fine SiPM gain and dark noise adjustment at the system level to correct for the non-uniformity of SiPMs.
The power consumption is 5 mW/channel. Temporoc is suitable for any application that requires both accurate time resolution and precise energy measurement such as time-of-flight gamma detection.
|
Image
|
Name
|
Package
|
No. of Channels
|
Compatible Detectors
|
Input Polarity
|
Main Applications
|
Time Measurement
|
|
|
Discontinued TRIROC 1A |
TFBGA353 |
64 |
SiPM, SiPM array |
Negative, Positive |
PHA, ToF, Timing |
TDC |
|
|
Discontinued GEMROC 1 |
PQFP160 |
64 |
Micromegas GEMS |
Negative |
PHA, Timing |
Trigger-based |
|
|
Discontinued PETIROC 2A |
TQFP208, TFBGA353 |
32 |
SiPM, SiPM array, RPCs |
Negative, Positive |
PHA, ToF, Timing |
TDC |
|
|
Discontinued CATIROC 1 |
TQFP208 |
16 |
PMT, PMT array |
Negative |
PHA, Timing, Zero suppression |
TDC |
|
|
New PSIROC |
BGA516 |
64 |
PIN diodes, Silicon strips, GEMs |
Negative, Positive |
PHA, Energy mass. |
Trigger-based |
|
|
Discontinued CITIROC 1A |
PQFP160, TFBGA353 |
32 |
SiPM, SiPM array |
Positive |
PHA, Photon Counting |
Trigger-based |
|
|
Discontinued MAROC 3A |
TFBGA353 |
64 |
MA-PMT, PMT, SIPM, SiPM array |
Negative |
PHA, Photon counting |
Trigger-based |
|
|
New LIROC 1 |
BGA516 |
64 |
SIPM, SiPM array |
Negative, Positive |
PHA, Photon counting |
Trigger-based |
|
|
POPROC |
BGA516 |
64 |
MA-PMT, PMT |
Negative |
PHA, Photon counting |
Trigger-based |
|
|
Coming Soon RADIOROC 2 |
BGA516 |
64 |
SIPM, SiPM array |
Positive |
PHA, Photon counting |
Time and Charge (trigger) |
|
Detector Read-Out |
SiPM |
|
Number of Channel |
64 |
|
Signal Polarity |
Positive |
|
Sensitivity |
Trigger on first photo-electron |
|
Timing Resolution |
20 ps rms (TBC) |
|
Dynamic Range |
3000 photo-electrons (106 SIPM gain), Integral Non Linearity: 1% up to 2000 ph-e |
|
Packaging & Dimension |
BGA (20x20mm, 500 balls – TBC) |
|
Power Consumption |
Power supply: 1.2V, 330 mW |
|
Inputs |
64 voltage inputs with DC adjustment for SiPM HV tuning |
|
Outputs |
|
|
Internal Programmable Features |
|
|
Evaluation systems |
Evaluation board : 64 channels – available |