EASY Subsystem Power Supply Module
Magnetic field and radiation tolerant
12 floating 1.5 ÷ 8 V / 9 A channels
45 W maximum output power per channel
VMax and IMax set by trimmer for each channel
On/Off for each channel
Channels individually controlled and protected
Voltage Drop compensation via sense wires
Interlock capability
48 V Service local and remote on/off
The CAEN Mod. A3009 12 Channel 8 V / 9 A Power Supply Board is developed for operation in magnetic field and moderate radioactive environment. One A3009 houses 12 floating (reversible polarity) 8 V / 9 A / 45 W maximum output power channel. The connector output voltage range is 1.5 ÷ 8 V with 5 mV monitor resolution; channel control includes various alarms and protections.
|
APP30 connector APP30 1317G4 type connector for Mod.A3009, A3009R |
Consult our connectors reference page for technical information.
The board is provided with Remote Sensing Lines to compensate for the voltage drop over the connection cables.
Safety features allows the module to perform as a current generator and includes:
|
Channels |
can be enabled or disabled through the Global Interlock logic. |
|
Overvoltage and Undervoltage warning |
when the output voltage differs from the programmed value by more than 3% of voltage full scale range. |
|
Overcurrent detection |
When a channel attempts to exceed the programmed current limit, it signalled to be in “overcurrent” and enter in a TRIP status. The output voltage is varied to keep the current below the programmed limit for a programmable TRIP time, then the channel is switched off. If TRIP is set to “constant current mode”, the channel behaves like a current generator. |
|
Hardware VMAX and IMAX |
Maximum output voltage and maximum current value can be fixed via software with 5 mV resolution and the output voltage can not be programmed beyond this value. |
|
Image
|
Name
|
No. of Channels
|
Connectors
|
No. max of boards per crate
|
Width (slots)
|
Max power per channels
|
Iset/Imon resolution
|
Vset/Vmon resolution (mV)
|
Current Full Scale (A)
|
Voltage full Scale (V)
|
Max Ripple (mVpp)
|
|
|
A3009B |
12 |
Screw lock connectors |
5 |
4 |
45 W |
10 mA |
5 |
9 |
2 ÷ 8 |
20 |
|
|
A3602 |
3 |
DB37 |
10 |
2 |
35 W |
10 mA |
5 |
5 |
2 ÷ 7 |
5 |
|
|
A3025B |
4 |
Brass hexagon head bolt |
5 |
4 |
150 W |
100 mA |
5 |
25 |
2 ÷ 8 |
10 |
|
|
A3009 |
12 |
APP 1317G4 |
5 |
4 |
45 W |
10 mA |
5 |
9 |
2 ÷ 8 |
20 |
|
|
A3009H |
12 |
APP 1317G4 |
5 |
4 |
45 W |
10 mA |
5 |
9 |
6 ÷ 14 |
20 |
|
|
A3016 |
6 |
APP 1317G4 |
5 |
4 |
90 W |
10 mA |
5 |
16 |
2 ÷ 8 |
20 |
|
|
A3050B |
2 |
Brass hexagon head bolt |
5 |
4 |
300 W |
100 mA |
5 |
50 |
2 ÷ 8 |
10 |
|
|
A3100 |
1 |
APP PC5933T |
5 |
4 |
600 W |
100 mA |
5 |
100 |
2 ÷ 8 |
10 |
|
|
A3009HB |
12 |
Screw lock connectors |
5 |
4 |
45 W |
10 mA |
5 |
9 |
6 ÷ 14 |
20 |
|
|
A3050 |
2 |
APP PC5933T |
5 |
4 |
300 W |
100 mA |
5 |
50 |
2 ÷ 8 |
10 |
|
|
A3025 |
4 |
APP PC5933T |
5 |
4 |
150 W |
100 mA |
5 |
25 |
2 ÷ 8 |
10 |
|
|
New A3100HBP |
1 |
Brass hexagon head bolt |
5 |
4 |
600 W |
100 mA |
10 |
50 |
8 ÷ 14 |
10 |
|
|
A3006 |
6 |
APP 1317G4 |
5 |
4 |
90 W |
10 mA |
10 |
6 |
4 ÷ 16 |
20 |
|
|
A3016B |
6 |
Brass hexagon head bolt |
5 |
4 |
90 W |
10 mA |
5 |
16 |
2 ÷ 8 |
20 |
|
|
A3100B |
1 |
Brass hexagon head bolt |
5 |
4 |
600 W |
100 mA |
5 |
100 |
2 ÷ 8 |
10 |
|
No. of Channels |
12 |
|
Polarity |
Floating |
|
Output Voltage |
1.5 ÷ 8 V (connector output) The board works properly with a Vset larger than 1.25 V and a current on the load larger than 10 A |
|
Max. Output Current |
9 A |
|
Voltage Set/Monitor Resolution |
5 mV |
|
Current Set/Monitor Resolution |
10 mA |
|
VMAX hardware |
1.5 ÷ 8 V |
|
VMAX Hardware Accuracy |
± 2% of FSR |
|
VMAX software |
1.5 ÷ 8 V |
|
VMAX software resolution |
5 m V |
|
Voltage Ripple |
< 20 mV pp on 10 µF //0.1 µF 10Hz-15 MHz From 10 Hz to 15 MHz at full load; measured with the line terminated on a 10 μF capacitance and a 100 nF ceramic capacitance in parallel to the load |
|
Voltage Monitor vs. Output Voltage Accuracy |
max. ±30 mV ±0.3% of reading |
|
Voltage Set vs. Output Voltage Accuracy |
max. ±30 mV ±0.3% of reading |
|
Current Monitor vs. Output Current Accuracy |
± 0.05A ± 2% of reading From 10% to 90% of Full Scale Range |
|
Current Set vs. Output Current Accuracy |
± 0.05A ± 2% of reading |
|
Load Regulation |
|
|
Output Power (per Channel) |
45 W |
|
Test Set Up |
|
|
Weight |